Changzhou Pacific Electric Power Equipment Group’s 132kV power transformers feature low loss, low noise, high efficiency and strong reliability. Adopting advanced design and premium materials, they deliver excellent insulation, low partial discharge and high short‑circuit withstand strength. With stable performance, long service life and compact structure, our transformers are widely used in power grids, industrial and infrastructure projects. They ensure safe and stable operation under various working conditions, providing reliable power solutions for customers worldwide.
Introduction to 132kV (Um=145kV) Power Transformer
Our company's 132kV power transformer (with system maximum voltage Um=145kV) is suitable for transmission systems at the 132kV voltage level. The product focuses on the comprehensive control of losses, partial discharge, and noise. The structure ensures sufficient short-circuit resistance and sealing reliability. The core uses stepped joints and frame clamping, with complete grounding measures. The coils are calculated for potential distribution and field strength verification, and are wound with hard tubes and reinforced with external support bars. The entire phase of the transformer body is assembled as a whole, and the pressing system is preset with hydraulic pre-tightening force, ensuring good stability. The oil tank and oil reservoir both meet the requirements of full vacuum, and the oil filling process is strict to avoid residual bubbles. The product process is rigorous and suitable for power supply scenarios with high reliability requirements.
Product Parameters
| Rated Capacity (kVA) | Voltage Combination | Connection Group Symbol | No-load Loss (kW) | Load Loss (kW) (75℃) | No-load Current (%) | Short-circuit Impedance (%) | ||
| High Voltage (kV) | High Voltage (kV)% |
Low Voltage kV |
22 | |||||
| 3150 |
35~ 38.5 |
±2x2.5% 土5% |
3.15 6.3 10.5 |
Yd11 |
1.7 | 20.7 | 0.45 | 7.0 |
| 4000 | 2.0 | 24.6 | 0.45 | |||||
| 5000 | 2.4 | 28.2 | 0.35 | |||||
| 6300 | 2.9 | 31.5 | 0.35 | 8.0 | ||||
| 8000 | ±2x2.5% |
3.15 3.3 6.3 6.6 10.5 |
YNd11 | 4.0 | 34.6 | 0.30 | ||
| 10000 | 4.8 | 40.8 | 0.30 | |||||
| 12500 | 5.5 | 48.4 | 0.30 | |||||
| 16000 | 6.7 | 59.2 | 0.25 | |||||
| 20000 | 7.9 | 71.6 | 0.25 | |||||
| 25000 | 9.4 | 84.6 | 0.28 | 10.0 | ||||
| 31500 | 11.1 | 100.8 | 0.28 | |||||
|
Rated Capacity kV-A |
Voltage Combination | Connection Group Symbol | No-load Loss (kW) | Load Loss (kW) | No-load Current (%) | Short-circuit Impedance (%) | |
| High Voltage and Tap Range (kV) | Low Voltage | 22 | |||||
| 6300 |
110±2x2.5% 115±2x2.5% 121±2x2.5% |
6.3 6.6 10.5 |
YNd11 | 4.1 | 32.0 | 0.62 | 10.5 |
| 8000 | 4.9 | 38.0 | 0.62 | ||||
| 10000 | 5.8 | 45.0 | 0.58 | ||||
| 12500 | 6.8 | 53.0 | 0.58 | ||||
| 16000 | 8.3 | 65.7 | 0.54 | ||||
| 20000 | 9.7 | 79.0 | 0.54 | ||||
| 25000 | 11.4 | 94.0 | 0.50 | ||||
| 31500 | 13.5 | 111 | 0.48 | ||||
| 40000 | 16.2 | 133 | 0.45 | ||||
| 50000 | 19.4 | 158 | 0.42 | ||||
| 63000 | 22.9 | 187 | 0.38 | ||||
| 75000 |
13.8 15.75 18 21 |
26.0 | 212 | 0.33 | 12~14 | ||
| 90000 | 29.9 | 245 | 0.30 | ||||
| 120000 | 37.3 | 303 | 0.27 | ||||
| 150000 | 44.1 | 359 | 0.24 | ||||
| 180000 | 49.5 | 411 | 0.20 | ||||
|
Note 1: For step-up transformers, a tapless structure is recommended. Taps can be provided if required by operation. Note 2: When the annual average load factor of the transformer is between 42% and 46%, the maximum operating efficiency can be achieved using the loss values in the table. | |||||||
|
Rated Capacity kV-A |
Voltage Combination | Connection Group Symbol | No-load Loss (kW) | Load Loss (kW) | No-load Current (%) | Short-circuit Impedance (%) | |
| High Voltage and Tap Range (kV) | Low Voltage | 22 | |||||
| 31500 |
220±2×2.5% 242±2×2.5% |
6.3 6.6 10.5 |
YNd11 | 15 | 115 | 0.56 | 12~14 |
| 40000 | 18 | 134 | 0.56 | ||||
| 50000 | 21 | 161 | 0.52 | ||||
| 63000 | 25 | 188 | 0.52 | ||||
| 75000 |
10.5 13.8 |
29 | 213 | 0.48 | |||
| 90000 | 34 | 246 | 0.44 | ||||
| 120000 | 41 | 304 | 0.44 | ||||
| 150000 |
10.5、13.8 11、13.8 15.75 18、20 |
49 | 360 | 0.40 | |||
| 160000 | 51 | 378 | 0.39 | ||||
| 180000 | 56 | 413 | 0.36 | ||||
| 240000 | 70 | 484 | 0.33 | ||||
| 300000 |
15.75 18 20 |
83 | 577 | 0.30 | |||
| 360000 | 95 | 662 | 0.30 | ||||
| 370000 | 97 | 675 | 0.30 | ||||
| 400000 | 103 | 716 | 0.28 | ||||
| 420000 | 106 | 742 | 0.28 | ||||
| Note 1: Transformers with a rated capacity of less than 31500 kVA and those with other voltage combinations can also be provided upon request.Note 2: Transformers with a low voltage of 35 kV and 38.5 kV can also be provided upon request. | |||||||
Product Introduction
Transformer Features
Our company manufactures transformers with the following characteristics: low loss, low noise, low partial discharge, no leakage, and strong short-circuit resistance. They do not require core lifting during on-site installation, and the transformer body is maintenance-free for 20 years. Below are the main features of transformers with voltage ratings below 110 kV in terms of structure and process.
Core Section
1.Core Material and Structure
High-performance grain-oriented silicon steel sheets are selected for the core. The core adopts a fully oblique multi-stage step joint structure, and the non-overlapping yoke process is used, which helps reduce no-load losses and noise.
2.Core Assembly
The core column and yoke are bound using high-strength resin mesh banding materials, mechanically bundled and cured. This ensures good core perpendicularity.
3.Mechanical Strength
The core structure has high mechanical strength. Notably, the frame structure made of large laminated clamp plates effectively clamps the core together, ensuring sufficient short-circuit mechanical strength. This design also meets the requirement for no core lifting during transportation and on-site installation.
4.Core Connectors
All core structural components are rounded to avoid sharp edges. In areas with high field strength where lead wires pass through, special insulation sheaths are added to reduce partial discharge.
5.Electrical Reliability
All core component connections are left unpainted to ensure reliable electrical connection and prevent localized electrical potential. Both the clamps and core are grounded separately.
Coil Section
1.Electrical Structure Design
Electrical structural parameters are calculated using analysis software.
2.Voltage Distribution
All coils are analyzed using wave process calculation software for voltage distribution and repeatedly adjusted to ensure a reasonable gradient distribution. The electrical field strength of the transformer body is also verified to ensure optimal main longitudinal insulation parameters and electrical strength.
3.Coil Insulation
All coils are wound on hard insulation tubes that have been pre-dried and impregnated with oil for pre-stabilization. The outer coils are supported with external support strips, and additional auxiliary support strips are added inside the inner coils to improve short-circuit resistance.
4.Short-Circuit Resistance
Based on short-circuit mechanical force calculations, self-adhesive transposed conductors or semi-rigid conductors are used for the inner coils, which have extremely high mechanical strength and meet short-circuit resistance requirements.
5.Enhanced Short-Circuit Strength
All coil terminals and end parts are bound with high-shrink polyester heat-shrink tubes and heat-shrink tapes to increase short-circuit resistance.
6.Coil Structure and Cooling
The inner and outer coil spacers are designed based on calculated values and may differ, ensuring a rational distribution. The coils are equipped with a guided cooling structure for optimal heat dissipation. In addition, heat-pressed insulation molded parts replace traditional cardboard spacer strips at the coil transposition points. The oil gap spacer blocks are rounded and pre-impregnated, improving axial short-circuit resistance.
7.Vacuum Drying and Assembly
After vacuum drying, individual coils are assembled in phase. The main oil gap spacers between the coils are fixed using special positioning plates. After vacuum drying the coils, their heights are checked and adjusted to ensure that coils in the same phase are under consistent load, improving short-circuit strength.
Transformer Body Section
1.Body Structure
The transformer body adopts a single-phase structure. The body press plates are made of laminated insulation board or laminated wood, which have sufficient short-circuit impact resistance.
2.Compression Structure
The compression structure of the body uses laminated insulation board press blocks instead of traditional nails, increasing the cross-sectional area of the compression blocks and reducing the compression force. This structure uses hydraulic devices to set a pre-compression force during assembly after the drying process.
3.Lead Supports
All lead supports are made of high-density laminated wood and form a frame structure. Some lead supports are formed using laminated insulation paperboard, which increases both mechanical and electrical strength. All supports use laminated wood insulation nuts with a special anti-loosening structure.
Oil Tank and Assembly Section
1.Vacuum Oil Tank
All transformers rated for 110 kV and below use a fully vacuum-sealed oil tank with a barrel-shaped structure. The upper and lower sections of the oil tank can be connected either by bolts or welded to meet the requirement for no core lifting and maintenance-free operation. The inside of the oil tank is fully polished and rounded.
2.Oil Conservator
All transformer oil conservators can withstand full vacuum strength and are equipped with airbags and pointer-type oil level indicators. After all transformer accessories are assembled, the conservator can be evacuated to a full vacuum before oil injection, effectively preventing the formation of bubbles inside the insulation components and transformer, reducing partial discharge.
3.Sealing Structure
The sealing surfaces of the transformer, including bushings, adopt a hard connection structure with limit grooves, and high-quality sealing components are used with sealing adhesives to ensure no leakage.
4.Positioning and Reliability
The transformer is equipped with a special upper and lower positioning structure, which ensures reliability, resistance to transportation shocks, and meets the requirement for no core lifting during installation.
5.Secondary Wiring
Secondary wiring is arranged according to the user’s requirements, using stainless steel cable trays or armored cables, and all wiring is connected to terminal boxes to facilitate user installation.
6.Advanced Assembly Process
The transformer body undergoes an equivalent exposure time control from drying to vacuum oil impregnation, ensuring continuous high-vacuum degassing during the assembly of all accessories. This effectively controls moisture absorption in insulation components.
Quality Control
Our company’s entire transformer production process follows an advanced process management system for quality control. Processes such as wire production, insulation material fabrication, coil manufacturing, and body assembly are all carried out in dust-free work zones, with the air cleanliness controlled to 3 μg/cm²·day or below.
Company Profile
Changzhou Pacific Electric Equipment (Group) Co., Ltd. Is a reliable supplier in the field of high and low voltage power transmission and distribution equipment in China. It focuses on providing high-reliability power equipment solutions for global customers. The company was established in 1989 and became a group in 1997, with a registered capital of 130 million yuan. It has established its market position by offering reliable product performance.
The company operates a modern production base covering an area of 240,000 square meters. The building area is 120,000 square meters, with fixed assets amounting to 500 million yuan. The annual production capacity exceeds 20,000 sets, providing a production capacity guarantee for the reliability of the products.
Our core advantage lies in the durability and reliability of our products, as well as their extensive validation:
Industry reliability practitioners: As a member of the leadership team of the China Electrical Equipment Industry Association and its specialized branches, the company actively participates in the formulation of reliability standards and technical exchanges, and promotes the improvement of the industry's reliability level.
Proven complete solution: Offers mature products covering all aspects of power transmission and distribution, including high-voltage switch cabinets, transformers, ring-main units, and low-voltage intelligent distribution systems. All products have been verified through extensive practical applications, and the system has excellent compatibility.
Research and development centered on reliability: The company is a national-level high-tech enterprise. Its research focus is on the long-term operational reliability, environmental adaptability, and fault prevention of the products. It enhances product lifespan by applying intelligent monitoring and advanced material technologies.
Manufacturing for reliability: Strictly follow reliability-oriented manufacturing processes. Key components are produced in a clean environment. Implement tests and aging experiments that exceed industry standards to ensure that the factory-finished products have outstanding reliability performance.
Extensive reliability verification results: Over the past 30 years, the company's products have operated stably in key national power projects, rail transit systems, data centers, and overseas power projects. With an outstanding reliability record, it has established a market reputation.
Service commitment based on reliability: Adhering to the corporate spirit of "professionalism, integrity, cooperation, and innovation", we provide reliability support and services throughout the entire product lifecycle. We regard reliability as the foundation and are committed to becoming the most reliable power equipment partner for our customers.
Thanks to the proven product reliability and the well-established service system, the company has become the preferred supplier for numerous major projects both at home and abroad.