Changzhou Pacific Electric Power Equipment Group’s 35kV power transformers feature low loss, low noise, high efficiency and strong reliability. Adopting advanced design and premium materials, they deliver excellent insulation, low partial discharge and high short‑circuit withstand strength. With stable performance, long service life and compact structure, our transformers are widely used in power grids, industrial and infrastructure projects. They ensure safe and stable operation under various working conditions, providing reliable power solutions for customers worldwide.
35kV Voltage-Class Power Transformer
The 35kV voltage-class power transformer produced by our company is specially designed for power distribution networks and industrial users. It features low loss, low noise, low partial discharge, maintenance-free with a housing lifting mechanism, and excellent short-circuit resistance. The core is made of high-magnetic-conductivity silicon steel sheets and uses a full inclined multi-level stepped joint process, effectively controlling no-load loss and noise. The coil is optimized through wave process calculation and is wound using a hard insulation tube and reinforced structure, with high mechanical strength. The casing is a complete-phase assembly, with a stable pressing system. The oil tank is a fully sealed barrel-shaped structure, using hard connection sealing and full vacuum oil injection technology, ensuring no leakage for a long time. This product is suitable for the 35kV system, with a compact structure, high reliability, and meeting the 20-year maintenance-free design requirements.
Product Parameters
| Rated Capacity (kVA) | Voltage Combination | Connection Group Symbol | No-load Loss (kW) | Load Loss (kW) (75℃) | No-load Current (%) | Short-circuit Impedance (%) | ||
| High Voltage (kV) | High Voltage (kV)% |
Low Voltage kV |
22 | |||||
| 3150 |
35~ 38.5 |
±2x2.5% 土5% |
3.15 6.3 10.5 |
Yd11 |
1.7 | 20.7 | 0.45 | 7.0 |
| 4000 | 2.0 | 24.6 | 0.45 | |||||
| 5000 | 2.4 | 28.2 | 0.35 | |||||
| 6300 | 2.9 | 31.5 | 0.35 | 8.0 | ||||
| 8000 | ±2x2.5% |
3.15 3.3 6.3 6.6 10.5 |
YNd11 | 4.0 | 34.6 | 0.30 | ||
| 10000 | 4.8 | 40.8 | 0.30 | |||||
| 12500 | 5.5 | 48.4 | 0.30 | |||||
| 16000 | 6.7 | 59.2 | 0.25 | |||||
| 20000 | 7.9 | 71.6 | 0.25 | |||||
| 25000 | 9.4 | 84.6 | 0.28 | 10.0 | ||||
| 31500 | 11.1 | 100.8 | 0.28 | |||||
|
Rated Capacity kV-A |
Voltage Combination | Connection Group Symbol | No-load Loss (kW) | Load Loss (kW) | No-load Current (%) | Short-circuit Impedance (%) | |
| High Voltage and Tap Range (kV) | Low Voltage | 22 | |||||
| 6300 |
110±2x2.5% 115±2x2.5% 121±2x2.5% |
6.3 6.6 10.5 |
YNd11 | 4.1 | 32.0 | 0.62 | 10.5 |
| 8000 | 4.9 | 38.0 | 0.62 | ||||
| 10000 | 5.8 | 45.0 | 0.58 | ||||
| 12500 | 6.8 | 53.0 | 0.58 | ||||
| 16000 | 8.3 | 65.7 | 0.54 | ||||
| 20000 | 9.7 | 79.0 | 0.54 | ||||
| 25000 | 11.4 | 94.0 | 0.50 | ||||
| 31500 | 13.5 | 111 | 0.48 | ||||
| 40000 | 16.2 | 133 | 0.45 | ||||
| 50000 | 19.4 | 158 | 0.42 | ||||
| 63000 | 22.9 | 187 | 0.38 | ||||
| 75000 |
13.8 15.75 18 21 |
26.0 | 212 | 0.33 | 12~14 | ||
| 90000 | 29.9 | 245 | 0.30 | ||||
| 120000 | 37.3 | 303 | 0.27 | ||||
| 150000 | 44.1 | 359 | 0.24 | ||||
| 180000 | 49.5 | 411 | 0.20 | ||||
|
Note 1: For step-up transformers, a tapless structure is recommended. Taps can be provided if required by operation. Note 2: When the annual average load factor of the transformer is between 42% and 46%, the maximum operating efficiency can be achieved using the loss values in the table. | |||||||
|
Rated Capacity kV-A |
Voltage Combination | Connection Group Symbol | No-load Loss (kW) | Load Loss (kW) | No-load Current (%) | Short-circuit Impedance (%) | |
| High Voltage and Tap Range (kV) | Low Voltage | 22 | |||||
| 31500 |
220±2×2.5% 242±2×2.5% |
6.3 6.6 10.5 |
YNd11 | 15 | 115 | 0.56 | 12~14 |
| 40000 | 18 | 134 | 0.56 | ||||
| 50000 | 21 | 161 | 0.52 | ||||
| 63000 | 25 | 188 | 0.52 | ||||
| 75000 |
10.5 13.8 |
29 | 213 | 0.48 | |||
| 90000 | 34 | 246 | 0.44 | ||||
| 120000 | 41 | 304 | 0.44 | ||||
| 150000 |
10.5、13.8 11、13.8 15.75 18、20 |
49 | 360 | 0.40 | |||
| 160000 | 51 | 378 | 0.39 | ||||
| 180000 | 56 | 413 | 0.36 | ||||
| 240000 | 70 | 484 | 0.33 | ||||
| 300000 |
15.75 18 20 |
83 | 577 | 0.30 | |||
| 360000 | 95 | 662 | 0.30 | ||||
| 370000 | 97 | 675 | 0.30 | ||||
| 400000 | 103 | 716 | 0.28 | ||||
| 420000 | 106 | 742 | 0.28 | ||||
| Note 1: Transformers with a rated capacity of less than 31500 kVA and those with other voltage combinations can also be provided upon request.Note 2: Transformers with a low voltage of 35 kV and 38.5 kV can also be provided upon request. | |||||||
Product Introduction
Transformer Features
Our company manufactures transformers with the following characteristics: low loss, low noise, low partial discharge, no leakage, and strong short-circuit resistance. They do not require core lifting during on-site installation, and the transformer body is maintenance-free for 20 years. Below are the main features of transformers with voltage ratings below 110 kV in terms of structure and process.
Core Section
1.Core Material and Structure
High-performance grain-oriented silicon steel sheets are selected for the core. The core adopts a fully oblique multi-stage step joint structure, and the non-overlapping yoke process is used, which helps reduce no-load losses and noise.
2.Core Assembly
The core column and yoke are bound using high-strength resin mesh banding materials, mechanically bundled and cured. This ensures good core perpendicularity.
3.Mechanical Strength
The core structure has high mechanical strength. Notably, the frame structure made of large laminated clamp plates effectively clamps the core together, ensuring sufficient short-circuit mechanical strength. This design also meets the requirement for no core lifting during transportation and on-site installation.
4.Core Connectors
All core structural components are rounded to avoid sharp edges. In areas with high field strength where lead wires pass through, special insulation sheaths are added to reduce partial discharge.
5.Electrical Reliability
All core component connections are left unpainted to ensure reliable electrical connection and prevent localized electrical potential. Both the clamps and core are grounded separately.
Coil Section
1.Electrical Structure Design
Electrical structural parameters are calculated using analysis software.
2.Voltage Distribution
All coils are analyzed using wave process calculation software for voltage distribution and repeatedly adjusted to ensure a reasonable gradient distribution. The electrical field strength of the transformer body is also verified to ensure optimal main longitudinal insulation parameters and electrical strength.
3.Coil Insulation
All coils are wound on hard insulation tubes that have been pre-dried and impregnated with oil for pre-stabilization. The outer coils are supported with external support strips, and additional auxiliary support strips are added inside the inner coils to improve short-circuit resistance.
4.Short-Circuit Resistance
Based on short-circuit mechanical force calculations, self-adhesive transposed conductors or semi-rigid conductors are used for the inner coils, which have extremely high mechanical strength and meet short-circuit resistance requirements.
5.Enhanced Short-Circuit Strength
All coil terminals and end parts are bound with high-shrink polyester heat-shrink tubes and heat-shrink tapes to increase short-circuit resistance.
6.Coil Structure and Cooling
The inner and outer coil spacers are designed based on calculated values and may differ, ensuring a rational distribution. The coils are equipped with a guided cooling structure for optimal heat dissipation. In addition, heat-pressed insulation molded parts replace traditional cardboard spacer strips at the coil transposition points. The oil gap spacer blocks are rounded and pre-impregnated, improving axial short-circuit resistance.
7.Vacuum Drying and Assembly
After vacuum drying, individual coils are assembled in phase. The main oil gap spacers between the coils are fixed using special positioning plates. After vacuum drying the coils, their heights are checked and adjusted to ensure that coils in the same phase are under consistent load, improving short-circuit strength.
Transformer Body Section
1.Body Structure
The transformer body adopts a single-phase structure. The body press plates are made of laminated insulation board or laminated wood, which have sufficient short-circuit impact resistance.
2.Compression Structure
The compression structure of the body uses laminated insulation board press blocks instead of traditional nails, increasing the cross-sectional area of the compression blocks and reducing the compression force. This structure uses hydraulic devices to set a pre-compression force during assembly after the drying process.
3.Lead Supports
All lead supports are made of high-density laminated wood and form a frame structure. Some lead supports are formed using laminated insulation paperboard, which increases both mechanical and electrical strength. All supports use laminated wood insulation nuts with a special anti-loosening structure.
Oil Tank and Assembly Section
1.Vacuum Oil Tank
All transformers rated for 110 kV and below use a fully vacuum-sealed oil tank with a barrel-shaped structure. The upper and lower sections of the oil tank can be connected either by bolts or welded to meet the requirement for no core lifting and maintenance-free operation. The inside of the oil tank is fully polished and rounded.
2.Oil Conservator
All transformer oil conservators can withstand full vacuum strength and are equipped with airbags and pointer-type oil level indicators. After all transformer accessories are assembled, the conservator can be evacuated to a full vacuum before oil injection, effectively preventing the formation of bubbles inside the insulation components and transformer, reducing partial discharge.
3.Sealing Structure
The sealing surfaces of the transformer, including bushings, adopt a hard connection structure with limit grooves, and high-quality sealing components are used with sealing adhesives to ensure no leakage.
4.Positioning and Reliability
The transformer is equipped with a special upper and lower positioning structure, which ensures reliability, resistance to transportation shocks, and meets the requirement for no core lifting during installation.
5.Secondary Wiring
Secondary wiring is arranged according to the user’s requirements, using stainless steel cable trays or armored cables, and all wiring is connected to terminal boxes to facilitate user installation.
6.Advanced Assembly Process
The transformer body undergoes an equivalent exposure time control from drying to vacuum oil impregnation, ensuring continuous high-vacuum degassing during the assembly of all accessories. This effectively controls moisture absorption in insulation components.
Quality Control
Our company’s entire transformer production process follows an advanced process management system for quality control. Processes such as wire production, insulation material fabrication, coil manufacturing, and body assembly are all carried out in dust-free work zones, with the air cleanliness controlled to 3 μg/cm²·day or below.
Company Profile
Changzhou Pacific Electric Equipment (Group) Co., Ltd. Is a leading high-tech enterprise in the field of power transmission and distribution equipment manufacturing in China. It integrates the research and development, manufacturing, sales and service of high and low voltage equipment. The company was established in 1989 and was reorganized into a group in 1997, with a registered capital of 130 million yuan. It has now grown into an important force in the industry.
The company has a modern industrial base covering an area of 240,000 square meters and a construction area of 120,000 square meters. Its fixed assets amount to 500 million yuan, and the annual production capacity of various electrical equipment exceeds 20,000 sets.
Our core strengths and capabilities:
Industry Leadership and Influence: The company is a regular member of the China Electrical Equipment Industry Association and the China Electrical Engineering Society. It also serves as the vice-chairman of the Electrical Control and Distribution Equipment Branch and the High Voltage Switchgear Equipment Branch, and actively participates in the formulation of industry standards and the guidance of technical directions.
Complete product ecosystem: Offers a product system covering all scenarios of power transmission and distribution, ranging from high-voltage switch cabinets, transformers, ring-main units to low-voltage distribution cabinets, intelligent circuit breakers, and overall substation solutions. It possesses the capabilities of one-stop service and seamless integration.
Technology and Innovation-driven: As a national-level high-tech enterprise, we adhere to investment in research and development, focus on the development of intelligent, environmentally friendly, and highly reliable products, integrate technologies such as IoT sensing, digital control, and ecological design, and enhance the safety and operational efficiency of the power grid.
Precision quality and manufacturing excellence: The production process adheres to advanced management systems and international standards (such as GB, IEC, ANSI), and key processes such as coil winding, insulation treatment, and assembly are carried out in controlled clean environments to ensure product quality and consistency. A complete testing center is equipped to guarantee that each product meets strict performance and reliability standards.
Reputable track record and wide application: Over the past 30 years, our products have been successfully applied in numerous key fields both domestically and internationally, including national power grid projects, urban rail transit, data centers, industrial parks, and new energy projects. They are renowned for their durability, safety, reliability, and low total life cycle costs.
Customer-centered service philosophy: Adhering to the corporate spirit of "professionalism, integrity, cooperation, and innovation", we are committed to providing customized solutions and full lifecycle technical support. We insist on being vigilant even in times of peace and continuously improving, and work hand in hand with customers to build the future of power infrastructure.
Guided by these principles, the company has gained the continuous trust and recognition from government departments and a wide range of customers, and has become a reliable partner in the process of power system construction and modernization.